Skip to content
D-FENCE Electronic Fencing and Security Systems Ltd.D-FENCE Electronic Fencing and Security Systems Ltd.

The threat · Open land too long to watch?

D-Field Fence

Standard field fencing with D-FENCE sensor posts: fast to deploy along long open perimeters, as a retrofit or stand-alone.

Patented
15 kg triggerZones up to 90 mRetrofit or stand-alone
Render: green D-FENCE sensor posts in a field fence around a crop field, with a tractor working behind

Kilometres of open field, no early warning?

Farms, reservoirs, railways and pipelines run through open country, often with no fence at all or only a simple wire one. Crossing it is easy, and nobody is told.

01

Fast over long distances

Built on standard field fencing; no special skills or tools needed.

02

Retrofit or stand-alone

Add it to an existing fence or wall, or build a new line where there is none.

03

No high voltage

Electronic detection instead of a shock fence: no 10,000 V, no radiation.

The D-Field Fence builds on well-known, cost-effective field-type fencing. D-FENCE sensor posts are set into the fence line at any height the site needs, without special skills or tools, and a climb or cut on the wire raises an alarm with its location.

Fit it to an existing fence or wall, or put up a stand-alone line where there is no fence. It belongs to D-FENCE's Green Security Revolution family: electronic detection instead of a high-voltage shock fence.

From the first touch to the right response.

  1. Sensor posts in the line

    D-FENCE sensor posts carry the field-fence wire at the height you need.

  2. Force on the wire

    A climb or a cut adds load; typically 15 kg above the static load triggers the alarm.

  3. Processing unit

    Up to 24 sensors per unit, in zones of up to 90 m.

  4. Alarm out

    Dry contact or RS232 / RS485 to your alarm system, cameras or D-Command Control.

Seen in full.

Every image opens full size. Product sheets are shown whole, exactly as D-FENCE publishes them.

Specifications & documents.

SpecificationsD-Field Fence
Fence length
Practical limitation only
Zone length
Up to 90 m
Fence height
To customer specification
Sensor unit
250 × 55 × 25 mm, 200 g
Processing unit
Up to 24 sensors
Minimum trigger force
Typically 15 kg above the static load
Dry contact
N.O. & N.C.
Power
48 VDC / 12 VDC
Communication
RS232 / RS485
Operating temperature
−25 °C to +72 °C (−13 °F to 162 °F)
Storage temperature
−55 °C to +80 °C (−67 °F to 176 °F)
Humidity
95%
Corrosion
Anti-corrosion treatment to MIL T 152; all parts stainless steel
False alarm rate (catalogue)
Less than 1 per km per 3 months (maximum)
Sensor MTBF
4.7 × 10⁸ h
MTTR
30 min
Warranty
10 years on the sensors
Installation
Retrofit on existing fences or walls, or stand-alone
Patent
Patented (CN utility model, granted 2019)

Specification text, ready for your tender.

Copy it into your specification. It describes the system by what it must do, so any alternative has to meet every point.

D-Field FenceTender specification textDatasheet
  1. General

    The system shall be D-Field Fence by D-FENCE Electronic Fencing and Security Systems Ltd. (ISO 9001:2015 certified quality management), or an approved equivalent that meets every requirement in this section.

  2. Function

    Standard field fencing with D-FENCE sensor posts: fast to deploy along long open perimeters, as a retrofit or stand-alone.

  3. The system shall provide

    • Field-fence based: Uses standard, cost-effective field-type fencing.
    • Any height: Installed at the height the site needs, without special skills or tools.
    • Retrofit or stand-alone: Add it to an existing fence or wall, or build a new line where there is no fence.
    • Green Security Revolution: No high voltage and no radiation: an electronic alternative to shock fences.
    • Up to 24 sensors per unit: Zones of up to 90 m, with the location of the attempt.
    • Open outputs: Dry contact N.O. & N.C. and RS232 / RS485.
  4. Technical requirements

    • Fence length: Practical limitation only
    • Zone length: Up to 90 m
    • Fence height: To customer specification
    • Sensor unit: 250 × 55 × 25 mm, 200 g
    • Processing unit: Up to 24 sensors
    • Minimum trigger force: Typically 15 kg above the static load
    • Dry contact: N.O. & N.C.
    • Power: 48 VDC / 12 VDC
    • Communication: RS232 / RS485
    • Operating temperature: −25 °C to +72 °C (−13 °F to 162 °F)
    • Storage temperature: −55 °C to +80 °C (−67 °F to 176 °F)
    • Humidity: 95%
    • Corrosion: Anti-corrosion treatment to MIL T 152; all parts stainless steel
    • False alarm rate (catalogue): Less than 1 per km per 3 months (maximum)
    • Sensor MTBF: 4.7 × 10⁸ h
    • MTTR: 30 min
    • Warranty: 10 years on the sensors
    • Installation: Retrofit on existing fences or walls, or stand-alone
    • Patent: Patented (CN utility model, granted 2019)
  5. Detection sequence

    1. Sensor posts in the line: D-FENCE sensor posts carry the field-fence wire at the height you need.
    2. Force on the wire: A climb or a cut adds load; typically 15 kg above the static load triggers the alarm.
    3. Processing unit: Up to 24 sensors per unit, in zones of up to 90 m.
    4. Alarm out: Dry contact or RS232 / RS485 to your alarm system, cameras or D-Command Control.
  6. Submittals

    Before installation, the contractor shall submit the manufacturer's datasheet, the installation instructions and the zone layout for approval.

Discuss your project.

Tell us the site, the threat and the line. D-FENCE engineers will propose the right barrier, sensor and platform, ready for your integrator.

Build the full line.